|
Laursen & Tourbo Galaxy Patient Monitor Anesthesia EquipStat Medical Equipment, Inc provides New and Refurbished Surgical, Imaging and Medical Equipment of most. Display: (640 x 480 pixel) RGB Compatible with VGA monitor (CRT / TFT LCD) Wave form field: Configurable screen for maximum 4 wave forms (ECG, Pleth, Resp, Invasive BP or Capnography). Possible to view any 4 ECG leads, if 5-lead ECG cable is connected. Digital field: HR/PR, Resp, SpO2, Temp (T1, T2 or ?T) P1, P2 and NIBP (systolic, Diastolic and Mean), EtCO2 and FiCO2. On screen display of alarm limits or alarm disable status. Trace speed: 12.5, 25 or 50 mm/sec for ECG, Invasive pressure waveform and Plethysmograph. 6.25, 12.5 or 25 mm/sec for Respiration and side Capnogram (with 14", 640 480 pixel display) Optical Encoder: Rapid access to all the functions and parameter settings through single knob. Quick action hot keys for alarm mute, NIBP start/stop, IBP zero, recorder on/off, freeze and return to the main screen. 3/5 lead ECG monitoring: Automatic detection of 3 or 5 lead ECG cable. Display of I, II, III with 3-lead cable and I, II, III, AVR, aVL, aVF and V with 5-lead cable. In built cautery and defibrillator protection. HR range 20 to 270 bpm Programmable arrhythmia detection (Bradycardia, Tachycardia, Asystole, Irregular and skipped beat) Respiration: Impedance pneumography principle. Display of respiration waveform with respiration rate. Respiration range: 4 to 150 bpm User selectable aponea alarm delay: 5 - 90 sec. (steps of 5 sec.) Capnography (CO2): Side stream Capnography with display of CO2 waveform and digital values of EtCO2 and FiCO2. CO2 gets priority for calculation of respiration rate. Gain 20,40,60 and 80 mmHg. Flow rate: 140 ml/min. (+20 / -10) CO2 measurement is possible in mmHg /Kpa / Vol% EtCO2 range: 0 - 80 mmHg FiCO2 range: 2 - 20 mmHg Aponea alarm delay: 30 sec Temperature: Simultaneous monitoring of two temperatures. Display of T1 and T2 or ?T (if difference between T1 and T2 is less than 9.9ºC) Temperature range: 12 ºC to 43 ºC Pulse Oximetry: Pitch variation with change in oxygen saturation. SpO2 range: 0 - 100% Display of Pulse strength, plethysmograph and SpO2 values. Accuracy: 100 to 70% (+/- 2 digits) 69 to 50% (+/- 3 digits) 49 to 0% (unspecified) Accuracy in neonatal monitoring 100 to 70% (+/- 3 digits) Non-invasive Blood Pressure: Oscillometric Principle. Display of Systolic, Diastolic and Mean pressure. Modes: manual, STAT (5 min), Automatic (interval 2 min to 90 min) Range: 20 to 255 mmHg. Accuracy: +/- 5 mmHg Invasive Blood Pressure: Simultaneous monitoring of 2 channels. Display of Systolic, Diastolic and Mean pressure with respective waveform of P1 and P2. Individual and common channel zeroing. Labeling facility with automatic limits /gain/color setting. Pressure channel overlapping option available. IBP range: 300, 150, 60, 30, 20 and 10 mmHg Measurement range: -40 to 300 mmHg Alarms: Alarm setting for all parameters. Patient alarm: Red flashing with audio and message indicator Equipment alarm: YELLOW flashing with audio and message indicator. Alarm auto set facility provided. Alarm suspend: Continuous YELLOW Auto setting of alarm for HR/PR, SpO2, P1, P2, EtCO2, FiCO2, Respiration and Temperature. Re-alarm facility: 30 min for acknowledged alarm. Trends: 24 hr of graphical and tabular trend for HR/PR, SpO2, P1, P2, EtCO2, FiCO2, respiration and temperature. NIBP trend: 240 reading tabular Alarm recall: Last 16 alarm events with date, time and message. 2hr zoom (30 sec resolution) for graphical trends with mark, record and print facility. Recording / Printing: Optional in-built dual channel thermal recorder for recording two waveforms (selectable) with numerical data and alarm status. NIBP and tabular trend recording with patient information. Direct / delayed / Continuous modes of recording. Record on alarm facility (selectable) Printing of ECG strip along with complete numerical data and patient information on optical ink-jet printer. General: Dimension: 100 H x 350 W x 300 D mm Weight: 8.3 kg with in-built batteries, Capnography and recorder. Interface possible with Skyline - L&T color central station. Power Supply: Universal power supply: 95-265V ac, 50/60 Hz Power ratings: 40 W Operating time: 30 min for fully charged battery (with extreme condition: NIBP 2 min interval, Capnography and recorder in use), or approx 2 hr under full charge condition (typical) Battery type: 12V, 4Ah lead acid Charging time: 90% charge in 12 hr for fully discharged battery |